Blue Sea Systems 7615 ATD Automatic Timer Disconnect

Item #: 78030
Manufacturer Item: 7615
Manufacturer: Blue Sea Systems
Min. Order Qty: 1
Available: 66
150.6000
EACH
Quantity:
Quantity Ea. Price Ext. Price
1 150.6000 150.60
66
RoHS Compliant
REACH Compliant
112.8400
EACH
Packaged for retail use only. For bulk product, see item 78030B (must be logged in to purchase bulk)
    • Blue Sea Systems 7615 ATD Automatic Timer Disconnect
    • Category: Battery Chargers
    • Manufacturer: Blue Sea Systems
    • Can be configured to be used as one of the following battery saving products
    • Sealed to IP67
    Timer Disconnect
    • 12VDC signal triggers relay to connect battery power to devices
    • When signal is removed the time is activated and will disconnect devices after a preset time
    • Timer ranges from 15 minutes to 4 hours
    Low Voltage Disconnect
    • Senses low battery voltage and automatically disconnects devices
    • Low voltage setting can be used in conjunction with Timer Disconnect. Low voltage will disconnect devices prior to preset time to preserve battery power
    Automatic Charging Relay
    • Automatically combines two batteries when charging, and isolates them when discharging
    • Single side sensing only monitors the voltage of the start battery
    • Ideal for auxiliary batteries that are AGM or significantly larger than the start battery
    Solenoid
    • 12VDC signal will connect or disconnect relay without any time delay   
    • Nominal Voltage: 12VDC
    • Amperage Operating Current: 175mA (closed) 4 mA (open)
    • Terminal Stud Torque: 140 in-lb (15.82 Nm)
    • Continuous Rating: The maximum current a switch is designed to conduct for an indefinite period - 120A
    • Intermittent Rating: The maximum amount of current a switch is designed to carry for a minimum of a designated period of time - 210A (5 min)
    • Cable Size to Meet Ratings: 1 Ga. (50mm)
    • Charge Sense Connect: 13.0V (3 sec)
    • Charge Sense Disconnect: 12.75V (10 sec)
    • Disconnect Time: 5 sec, 15 min, 30 min, 1 hr, 1.5 hr, 2 hr, or 4 hr
    • Input Voltage Range: 9.5-16VDC
    • Low Voltage Disconnect
    • 11.0V (10 sec)
    • 11.5V (10 sec)
    • 12.0V (10 sec)
    • Maximum Cable Size: 1/0 Ga. (50mm)
    • Terminal Ring Diameter Clearance: 1.12in (28.45mm)
    • Terminal Stud Size: 3/8 -16 (M10)
    • Over Voltage Lockout: 16.0V (5 sec)
    WARNING: Cancer and Reproductive Harm www.P65Warnings.ca.gov

    Battery Chargers

    Number of Batteries
    3
    Output Current
    120 Amps
    Input Voltage
    12V DC
    Output Voltage
    12VDC Output
    Component Type
    Automatic Charging Relay
    Customer Service Hours
    Monday-Friday 7:30AM-5:30PM CST